45641001TH Rev.1
11-42 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
Mode
System
User
interface
8722
Display method of
“Cannot find the
Home Directory”
on the control
panel
0
0-1
SYS Sets the display method of error if the Home Directory
for user cannot be obtained from the server when setting
the Home Directory for scanning. Use this code to disable
the pop-up display when the Home Directory cannot be
obtained depending on the user.
0: Displays the pop-up dialogue when user logs in
1: Displays the message in the guidance area when the
Scan to File screen is displayed
1
08
Setting
Mode
System
User
interface
8723
Pop-up display
of logging out of
user authentication
and department
management on
the control panel
1
0-1
SYS Sets whether the pop-up dialog of confirmation for logging
out is displayed when user or department logs out by
pressing [FUNCTION CLEAR] button twice or pressing
[ACCESS] button.
0: Logs out without displaying pop-up dialog
1: Displays pop-up dialog when logging out
1
08
Setting
Mode
System
User
interface
8724
Display setting of
Edit From Address
button for Scan to
email
1
0-1
SYS 0: Not displayed (From Address cannot be edited)
1: Displayed (From Address can be edited)
1
08
Setting
Mode
System
User
interface
8725
Display setting
of [USER
FUNCTIONS]->
CHANGE
LANGUAGE button
1
0-1
SYS
Sets whether the [CHANGE LANGUAGE] button
accessed from [USER FUNCTIONS] button is displayed
or not. Use this code to prohibit users from changing the
language displayed on the control panel. Administrators
can change the language.
0: Not displayed
1: Displayed
1
08
Setting
Mode
System
General
8726
Job deletion on the
Job Status screen
0
0-1
SYS
Use this code to enable the job deletion on the [Job
Status] screen. When “3: High level” is set for code 08-
8911, be sure to disable this setting.
0: Disabled
1: Enabled
1
08
Setting
Mode
System
User
interface
Card reading
device
8727
Display of
dedicated
screen for card
authentication
0
0-1
SYS Switches whether the message to hold a card over the
card reader is displayed on the login screen when the
card authentication is enabled.
0: Disabled
1: Enabled
1
08
Setting
Mode
System
General
8737
Restart behavior
when the out of
paper is solved
(bypass feeding)
1
0-1
SYS 0: Automatically restarted
1: Restarted by pressing the [START] button
1
08
Setting
Mode
System
User
interface
Display setting
8738
E-mail address
direct input button
1
0-1
SYS Switches the display setting of the [INPUT @] button.
0: Not displayed
1: Displayed
1
08
Setting
Mode
System
User
interface
Display setting
8744
Switchover of pop-
up display during
scanning
1
0-1
SYS Switches the pop-up display during scanning
0: Not displayed
1: Displayed
1
Содержание MB760