5.2.5
Web Page related error/Communication error with external application
Error code
Message displayed in the
Web Page screen
Contents
Troubleshooting
5010
-
Internal setting error: There is a print job,
a proof print job, a private print job, a
print job without a set department code,
a scan job or a fax job remaining in this
equipment.
P. 5-82
5012
Invalid temporary password
and permanent password
Authentication error: A temporary
password downloaded from e- Bridge
and entered in this equipment is not
valid, or the permanent password set in
the e- Bridge is not valid.
P. 5-82
5013
e-Bridge communication
error
e-Bridge communication error:
Communication is attempted while the
e-Bridge is enabled for some reason
such as version upgrade.
P. 5-82
5014
No SSL certificate
No SSL certificate: There is no SSL
certificate or the certificate is not in a
correct file format.
P. 5-82
5015
Invalid SSL certificate
Invalid SSL certificate: SSL certificate is
not valid.
P. 5-82
5016
Expired SSL
certificateIncorrect time in
MFP
Expired SSL certificate: SSL certificate
is expired.
P. 5-83
5017
Other SSL certificate related
error
Other SSL certificate related error: SSL
certificate is invalid.
P. 5-83
5018
Invalid DNS error
Invalid DNS error: DNS address is
invalid.
P. 5-83
5019
Connection error
Connection error: Settings for initial URL
and proxy are incorrect.
P. 5-83
501A
Proxy error
Proxy error: IP address or port for proxy
setting is invalid.
P. 5-83
501B
No URL (host/port) or invalid
path
No URL (host/port) or invalid path: Initial
URL is invalid.
P. 5-84
5030
HTTP communication error
An error in the HTTP communication
P. 5-84
50FF
eBR2 internal error
A fatal error occurred in the MFP
P. 5-84
5110
Toner Not Recognized -
Please Check Toner.
Toner cartridge detection error.
P. 5-84
5212
Time for Slit Glass and Main
Charger Cleaning - Please
Clean Slit Glass and Main
Charger.
Appears when the time for main charger
cleaning comes (at every output of
approx. 10,000 sheets)
P. 5-84
5BD0
Power failure occurred
during restore
Power supply is cut off during the
restoration of database sent from Web
Page
P. 5-85
5C10
FAX Unit is not attached.
Network FAX is disabled because the
FAX Unit is not attached
P. 5-85
5C11
Security error on Address
Book.
The network FAX job failed because the
specified address is not registered in the
Address Book
P. 5-85
Содержание MB760