45641001TH Rev.1
3-11 /
Oki Data CONFIDENTIAL
Procedure 7
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[Digital key]
(Sub code)
[CLEAR]
(Corrects value)
[START]
[START]
*[CANCEL] or [CLEAR]
[CANCEL]
[FAX]
[START]
(Test copy)
[OK]
Stores value
in RAM
Automatic
adjustment
* When the automatic adjustment ends abnormally, an error message is displayed.
* Return to standby screen by pressing the [CANCEL] or [CLEAR] button.
Procedure 10
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[Digital key]
(Sub code)
[START]
[START]
[START]
[OK] or [INTERRUPT]
(Value unchangeable)
Value
displayed
Procedure 12
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[START]
[CANCEL]
[Digital key]
(Key in a value)
[CLEAR]
(Corrects value)
[OK]
or
[INTERRUPT]
(Stores value in RAM)
[FAX]
[START]
(Test copy)
Manual
adjustment
Procedure 14
[0][5]
[POWER]
[POWER]
OFF/ON
(Exit)
[Digital key]
(Code)
[START]
[START]
[Digital key]
(Sub code)
[FUNCTION CLEAR]
(Corrects value)
[CLEAR]
(Corrects value)
[OK]
or
[INTERRUPT]
[FAX]
[START]
(Test copy)
(Input value)
Stores value
in RAM
Notes:
The fuser belt temperature control at the adjustment mode is different from that at the normal
state. Therefore, the problem of fusing efficiency may be occurred in the test copy at the
adjustment mode. In that case, turn ON the power normally, leave the equipment for approx. 3
minutes after it has become ready state and then start up the adjustment mode again.