45641001TH Rev.1
8-7 /
Oki Data CONFIDENTIAL
Notes:
• The display of items on this screen varies depending on the types of data written
on the USB device.
Each item is displayed only when each data file is written on the USB device in
the following conditions.
Item
Condition
1. SYSTEM FIRMWARE
(OS Data)
O290SF0Wxxxx.tar is written. (xxxx is version.)
2. ENGINE FIRMWARE
H291PUPWW.xxxx is written. (xxxx is version.)
3. SCANNER FIRMWARE
H282SUPWW.xxxx is written. (xxxx is version.)
4. SYSTEM SOFTWARE
(HD Data)
O290HD0Wxxxx.tar is written. (xxxx is version.)
• If the USB device is not recognized properly, “USB device Not detected” message
is displayed. In this case, disconnect the USB device and connect again within
3 minutes, or shut down the equipment and connect the device properly. Then
repeat the procedure from (4).
• If any of the error messages below is displayed, confirm if the data file in the USB
device is correct.
Then repeat the procedure from (4).
Error
number
Error message
Cause
01
Error Loadmodule
Module loading failed.
02
Machine Model Get Error
Model information was
not downloaded.
03
Copy Data with valid signature in USB Storage Checking of data file
failed.
04
Other models ROMDATA TXXXXXXXX
* The version name comes at “xxxx.xxx.x”.
Master data of other
model are stored.
05
Copy Signature File in USB Storage
Data files are not
stored in the USB
device.
06
Patch and Normal package in one folder
of USB Storage
When both the system
and patch update
packages are in the
USB device
(6) Select the item with the digital keys.
“*” is displayed next to the selected item. Display or delete the “*” by pressing the
number of the item.
Item
Remarks
1. SYSTEM FIRMWARE(OS Data)
Updating System firmware
2. ENGINE FIRMWARE
Updating PU firmware
3. SCANNER FIRMWARE
Updating SU firmware
4. SYSTEM SOFTWARE (HD Data)
Updating System software