45641001TH Rev.1
11-81 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
mode
System
Maintenance RDMS
Long interval
polling
9626
Setting of polling at
the end of month
0
0-1
SYS 0: Invalid
1: Valid
1
08
Setting
mode
System
Network
InternetFAX
9627
Sending mail text
of Internet FAX
1
0-1
SYS 0: Invalid
1: Valid
1
08
Setting
mode
System
Network
SMTP
9628
From Name
Creation setting
in SMTP
authentication
0
0-2
SYS 0: Not edited
1: Account name of From ADevice name
2: LDAP searching
1
08
Setting
mode
System
Wireless
LAN
9649
Wireless LAN
setting
2
1-2
NIC
Sets whether the wireless LAN connection is enabled or
disabled.
1: Enabled
2: Disabled
12
08
Setting
mode
System
Network
DHCP
9694
Enabling server’s
IP address
acquired by DHCP
1
1-2
-
DNS domain name Option (15) DNS domain name of the
client
1: Enabled
2: Disabled
This value is used only when DHCP is enabled.
12
08
Setting
Mode
System
Maintenance General
9700
Service technician
telephone number
0
32 digits SYS A telephone number can be entered up to 32 digits.
Use the [MONITOR/PAUSE] button to enter a hyphen(-).
11
08
Setting
mode
System
User
interface
9702
Automatic
calibration
disclosure level
1
0-2
SYS Sets the disclosing level of automatic calibration.
0: Service technician
1: Administrator
2: User
1
08
Setting
Mode
System
Maintenance General
9703
Error history
display
-
-
SYS Displays the latest 20 errors data
2
08
Setting
mode
System
Network
Scanning
9709
Default data saving
directory of “Scan
to File”
0
0-2
SYS
0: Local directory
1: REMOTE 1
2: REMOTE 2
1
08
Setting
Mode
System
Maintenance RDMS
General
9710
Remote-controlled
service function
2
0-2
SYS
0: Valid (Remote-controlled server)
1: Valid (L2)
2: Invalid
1
08
Setting
Mode
System
Maintenance RDMS
HTTP
9711
Remote-controlled
service URL
setting
-
-
SYS Maximum 256 letters
11
08
Setting
Mode
System
Maintenance RDMS
HTTP
9715
Initially-registered
server URL setting
Refer to
contents
-
SYS Maximum 256 letters
<Default value>
https://device.mfp-
support.com:443/device/firstregist.ashx
11
08
Setting
mode
System
Maintenance
(Remote)
RDMS
9718
Short time interval
setting of recovery
from Emergency
Mode
24
1-48
SYS Sets the time interval to recover from the Emergency
Mode to the Normal Mode. (Unit: Hour)
1