45641001TH Rev.1
11-20 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
Mode
System
User
interface
Card reading
device
3502
Card reader format
information -2
0
0-
42949
67295
SYS The data of the block number in the noncontact IC is set.
KP-2003: <PPQRSSTU (hexadecimal
number)>
PP: 1st block
Q: 1st block beginning byte
R: 1st block ending byte
SS: 2nd block
T: 2nd block beginning byte
U: 2nd block ending byte
KP-2005: <RRBSEbse (hexadecimal
number)>
RR: 00 (Fixed)
B: 1st area block number
S: 1st area beginning byte offset
E: 1st area ending byte offset
b: 2nd area block number
s: 2nd area beginning byte offset
e: 2nd area ending byte offset
* If the 2nd block/area is not used, set the SSTU
to
“FFFF”
(hexadecimal number), the bse
to”FFF” (hexadecimal
number).
5
08
Setting
Mode
System
User
interface
Card reading
device
3503
Card reader format
information -3
0
Refer to
contents
SYS
Security key “KKKKKKKKKKKK” (12
digits)
<hexadecimal number> in the [Key Information] of
the
[Sector Number] set in the code 08-3501 should
be entered.
<Acceptable value>
0-0xFFFFFFFFFFFFFFFF
5
08
Setting
Mode
System
User
interface
Card reading
device
3504
Card authentication
LDAP
server
0
0-100
SYS
LDAP server number for the card authentication
when a
noncontact IC card is used should be set.
1
08
Setting
mode
System
General
List print USB
storage setting
3615
List print USB
storage setting
0
0-1
SYS 0: Enable (USB storage available)
1: Disable (USB storage not available)
1
08
Setting
mode
System
General
Real time log
notification
function
3623
Job filtering setting
0
0-65535 SYS
Changes the target type of jobs for notification in
real
time log notification function.
1
08
Setting
mode
System
General
Real time log
notification
function
3624
Log item
filtering
setting
21474
83921
0-
42949
67295
SYS Changes the target type of logs for notification in real
time log notification function.
5
08
Setting
Mode
System
General
Real time log
notification function
3626
Department
information
transmission
setting
0
0-1
SYS
Sets whether the department information (number, name,
code) is transmitted or not in the real time log notification
function.
0: Department number, department name, department
code
1: Department number, department name
1
08
Setting
mode
System
General
3629
Enable/Disable
setting of standard
EWB function
1
0-1
SYS 0: Disabled
1: Enabled
1
Содержание MB760