45641001TH Rev.1
11-72 /
Oki Data CONFIDENTIAL
05/
08
Mode
Element
Sub
element
Item
Subitem
Code Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce-
dure
08
Setting
mode
System
Paper
feeding
Paper size (bypass
feeding/non-
standard type)
9320
Memory 3
127/64 127-356/
64-216
SYS Registers the paper size of bypass feed (non-standard
type) into [MEMORY 3].
Feeding/Widthwise direction.
10
08
Setting
mode
System
Paper
feeding
Paper size (bypass
feeding/non-
standard type)
9321
Memory 4
127/64 127-356/
64-216
SYS Registers the paper size of bypass feed (non-standard
type) into [MEMORY 4].
Feeding/Widthwise direction.
10
08
Setting
Mode
System
User
interface
Sound
9325
Key touch sound of
control panel
1
0-1
SYS 0: OFF
1: ON
1
08
Setting
mode
System
General
Banner advertising
9327
Setting of banner
advertising display
0
0-1
SYS Sets whether or not displaying the banner advertising.
The setting contents of 08-9328 and 9329 are displayed
at the time display section on the right top of the screen.
When both are set, each content is displayed alternately.
0: Not displayed
1: Displayed
1
08
Setting
mode
System
General
Banner advertising
9328
Banner advertising
display 1
-
-
SYS Maximum 27 letters (one-byte character)
11
08
Setting
mode
System
General
Banner advertising
9329
Banner advertising
display 2
-
-
SYS Maximum 27 letters (one-byte character)
11
08
Setting
mode
System
General
Banner advertising
9330
Display of
[BANNER
MESSAGE] button
0
0-1
SYS 0: Not displayed
1: Displayed
This button enables the entry of “Banner advertising
display 1 (08-9328)” and “Banner advertising display 2
(08-9329)” on the control panel.
1
08
Setting
mode
System
Network
9331
Local I/F time-out
period
6
1-50
SYS
Sets the period of time when the job is judged as
completed in local I/F printing (USB or parallel).
1: 1.0 sec.
2: 1.5 sec.
50: 25.5 sec.
(in increments of 0.5 sec.)
1
08
Setting
mode
System
User
interface
9332
Original counter
display
Refer to
contents
0-4
SYS Sets whether the original counter is displayed or not.
0: Not displayed
2: Displayed
4: Displayed (Double sized original is counted as 2.)
<Default value>
ODA/JP: 0
Others: 2
1
08
Setting
mode
System
Network
9334
PCL line feed code
setting
0
0-3
SYS
Sets the PCL line feed code.
0: Automatic setting
1: CR=CR, LF=LF
2: CR=CR+LF, LF=LF
3: CR=CR, LF=CR+LF
1