8.4 Clock box
The Clock Box is responsible for generating all clock signals for the system.
The PCR_CLK_CFG_REG and PCR_CLK_CFG2_REG are used by firmware to gate
system and IP clocks going to different modules.
The system clock source can be one among:
HFO
20 MHz
XTAL
27.12 MHz (internal test purpose)
CLK_USB/2
24 Mhz. (only internal test purpose)
System clock must be always 20 MHz
Fig 22. Clock Box control