NXP Semiconductors
UM10858
PN7462 family HW user manual
UM10858
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2018. All rights reserved.
User manual
COMPANY PUBLIC
Rev. 1.4 — 14 May 2018
314514
199 of 345
8:11 are not taken
into account.
DPC_GUARD_F
AST_MODE
0x20132E
wGuardTimeFastMode
R/W
2
Guard time after
AGC fast mode has
been triggered.
This happens in
the following
scenarios:
- End of Receive
- End of Transmit
- After a gear
switch
Time base is 1/20
MHz (Example:
Value of 2000 is
equal to 100us)
DPC_GUARD_S
OF_DETECTED
0x201330
wGuardTimeSofDetec
ted
R/W
2
Guard time after
SoF or SC
detection. This is to
avoid any DPC
regulation between
SoF/SC and actual
begin of reception.
Time base is
1/20MHz
(Example: Value of
2000 is equal to
100us)
DPC_GUARD_FI
ELD_ON
0x201332
wGuardTimeFieldOn
R/W
2
Guard time after
Gear Switch during
FieldOn instruction.
Time base is
1/20MHz
(Example: Value of
2000 is equal to
100us)
PCD_SHAPING_
LUT_SIZE
0x2013A8
bSizeOfLUT
R/W
1
Number of
elements for the
PCD Shaping
PCD_SHAPING_
LUT
0x201368-
0x2013a7
dwConfiguration
R/W
64
PCD Shaping
configuration
lookup table: Each
word contains the
following
information:
0..3: DPC Gear
4..7:
TAU_MOD_FALLI
NG (Sign bit + 3-bit
value)