— A-7 —
2 Initialize the Driver Unit.
(1)
Connect the Handy Terminal FHT11 to CN1 connector of the Driver Unit.
¯
(2)
Turn on the control power only.
¯
(3)
Input the password. When the colon “ : ” is displayed,
Press.
K
N
S
/
SP
N
ENT
O
¯
(4)
The Driver Unit echoes back “NSK ON”.
¯
(5)
Input “SI/AL” command.
Press.
A
I
/
S
L
¯
(6)
The Driver Unit echoes back “INITIALIZE”. A colon “ : ” will be displayed to indicate
completion of initializing.
3 Input the noted parameter settings and channel programs.
(1)
Firstly set “PA” parameter.
l
Input the password.
Press.
K
N
S
/
SP
N
ENT
O
The Driver Unit echoes back “NSK ON”.
¯
(2)
Press
*
A
*
P
ENT
(** must be the same data as noted.)
¯
(3)
Set other parameters and programs accordingly.
¯
(4)
Make sure that all parameters and programs are set properly.
l
Monitor the settings with “TS0” and “TCn” commands.
¯
(5)
Turn off the power.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Содержание MEGATHRUST ESA-LYB2T15-21
Страница 7: ...Blank Page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 23: ...3 4 Blank page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 35: ...4 12 Blank Page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 73: ...6 12 Blank Page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 155: ...11 10 Blank Page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 187: ...12 32 Blank Page Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 225: ...A 10 Figure A 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...
Страница 228: ...A 13 Figure A 16 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...