Chapter 25 — Fault locating and clearing
Page 491 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
Defective NTMW01
SSC
Install a new NTMW01 SSC card.
Note: Reuse the daughter board attached to the original
SSC card
.
Call processing on the entire system is interrupted while the
SSC
circuit card
is being replaced.
Enable and test the card by entering
LD 30
TEST
If the card tests “OK”, the NTMW01 SSC was defective.
If after a few minutes the problem recurs, and this system is not
equipped with an expansion cabinet, the shelf backplane is
defective. Replace the main cabinet.
If this system is equipped with an expansion cabinet, go to the next
possible cause.
Defective Expansion
cabinet
Replace cabinet if the affected PE card is in this cabinet.
Enable and test the card by entering
LD 30
TEST
If problem persists got to next possible cause
Defective Main cabinet
Replace cabinet.
Possible cause
Action
Содержание Meridian Meridian 1
Страница 3: ...553 3121 210 Standard 3 0 January 1999 ...
Страница 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Страница 89: ...Page 70 of 536 Chapter 6 Bracing cabinets against earthquakes 553 3121 210 Standard 3 0 January 1999 ...
Страница 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Страница 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Страница 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Страница 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Страница 139: ...Page 120 of 536 Chapter 13 Installing the circuit cards 553 3121 210 Standard 3 0 January 1999 ...
Страница 157: ...Page 138 of 536 Chapter 15 Installing and connecting SDI and Ethernet ports 553 3121 210 Standard 3 0 January 1999 ...
Страница 175: ...Page 156 of 536 Chapter 16 Starting up and testing the system 553 3121 210 Standard 3 0 January 1999 ...
Страница 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Страница 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Страница 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 455: ...Page 436 of 536 Chapter 24 Changing pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...