Chapter 15 – Installing and connecting SDI and Ethernet ports
553-3121-210
Standard 3.0
January 1999
Installing and connecting SDI ports
NTMW01 SSC
The baud rate for port 0 is controlled by a switch setting on the circuit card’s
faceplate. Ports 1 and 2 are user configurable using overlay program 17.
•
Port 0 is the only SDI port that can be used for software installation and
upgrades.
•
All three ports on the SSC card can be used to connect terminals.
•
Modems should only be connected to Port 0 since it is the only port that
supports Carrier Detect (CD).
•
An NTBK48 3-port SDI cable must be used with the NTMW01 SSC
card.
Note: The default baud rate of the SSC card is 19200 bps. When
changing the DIP switch on the faceplate, make sure only one baud rate
switch is set to ON (Refer to Table 13).
describes how to connect a terminal, modems and
other devices such as CDR devices and additional TTYs to the SSC card.
Table 13
Default port configuration for the NTMW01 SSC card
Port
Use
Baud rate
Data bits
Stop bits
Parity
0
MTC/SCH/BUG
Set by a DIP switch
8
1
None
1
MTC/SCH/BUG
1200 (See Note 1)
8
1
None
2
MTC/SCHBUG
1200 (See Note 2)
8
1
None
Содержание Meridian Meridian 1
Страница 3: ...553 3121 210 Standard 3 0 January 1999 ...
Страница 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Страница 89: ...Page 70 of 536 Chapter 6 Bracing cabinets against earthquakes 553 3121 210 Standard 3 0 January 1999 ...
Страница 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Страница 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Страница 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Страница 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Страница 139: ...Page 120 of 536 Chapter 13 Installing the circuit cards 553 3121 210 Standard 3 0 January 1999 ...
Страница 157: ...Page 138 of 536 Chapter 15 Installing and connecting SDI and Ethernet ports 553 3121 210 Standard 3 0 January 1999 ...
Страница 175: ...Page 156 of 536 Chapter 16 Starting up and testing the system 553 3121 210 Standard 3 0 January 1999 ...
Страница 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Страница 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Страница 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 455: ...Page 436 of 536 Chapter 24 Changing pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...