Chapter 25 — Fault locating and clearing
Page 455 of 536
Option 11C Compact
Planning, Installation, Fault Clearing and CCBR Guide
Except as excluded by the provisions of warranty or other agreements with
Nortel, a fee for technical assistance may be charged, provided at rates
established by Nortel. Information on rates and conditions for services are
available through Nortel sales representatives.
Table 61
Technical service emergency classifications
Class
Degree of failure
Symptoms
E1
Major failure causing system
degradation or outage
System out of service with complete loss of
call-processing capability
Loss of total attendant console capability
Loss of incoming or outgoing call capability
Call processing degraded for reasons such as trunk
group out of service
• 10% or more lines out of service
• Frequent initializations (seven per day or more)
• inability to recover from initialization or sysload
• consistently slow dial tone (eight seconds or more
delay)
E2
Major failure causing potential
system degradation or outage
Frequent initializations (one per day or more)
Содержание Meridian Meridian 1
Страница 3: ...553 3121 210 Standard 3 0 January 1999 ...
Страница 17: ...xiv Contents 553 3121 210 Standard 3 0 January 1999 ...
Страница 89: ...Page 70 of 536 Chapter 6 Bracing cabinets against earthquakes 553 3121 210 Standard 3 0 January 1999 ...
Страница 97: ...Page 78 of 536 Chapter 8 Installing a new system 553 3121 210 Standard 3 0 January 1999 ...
Страница 107: ...Page 88 of 536 Chapter 10 Installing the system ground 553 3121 210 Standard 3 0 January 1999 ...
Страница 113: ...Page 94 of 536 Chapter 11 Installing the power supply 553 3121 210 Standard 3 0 January 1999 ...
Страница 125: ...Page 106 of 536 Chapter 12 Adding an expansion cabinet 553 3121 210 Standard 3 0 January 1999 ...
Страница 139: ...Page 120 of 536 Chapter 13 Installing the circuit cards 553 3121 210 Standard 3 0 January 1999 ...
Страница 157: ...Page 138 of 536 Chapter 15 Installing and connecting SDI and Ethernet ports 553 3121 210 Standard 3 0 January 1999 ...
Страница 175: ...Page 156 of 536 Chapter 16 Starting up and testing the system 553 3121 210 Standard 3 0 January 1999 ...
Страница 209: ...Page 190 of 536 Chapter 18 Connecting the trunks 553 3121 210 Standard 3 0 January 1999 ...
Страница 323: ...Page 304 of 536 Chapter 21 Installing Hospitality 553 3121 210 Standard 3 0 January 1999 ...
Страница 419: ...Page 400 of 536 Chapter 23 Pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 455: ...Page 436 of 536 Chapter 24 Changing pre programmed data 553 3121 210 Standard 3 0 January 1999 ...
Страница 555: ...Page 536 of 536 Chapter 25 Fault locating and clearing 553 3121 210 Standard 3 0 January 1999 ...