Apex Classic Setup and Programming Guide v2.2
Page
80
Web Interface: Data Log – select the day and length of log you wish to
view from the selection boxes near the top of the page and click the Update
Button to view the log.
Figure 11 - Data Log
POWER FAIL LOG
All power failures to individual EnergyBars and Apex Base Modules are logged by
the AquaController Apex. The list of these failures can be found in the power fail
log.
To view the Power Fail Log:
Apex Display: Data Log – Power Fail Log – Power Log – lists the time
stamps when the power failed and when it was restored.
Web Interface: Status – the last power failure and power restore event is
listed at the bottom of the Status Screen.
To clear the Power Fail Log:
Apex Display: Data Log – Power Fail Log – Reset Log – the log is
immediately reset.
Web Interface: This option is not available from the Web Interface.
INITIALIZE MEMORY
The AquaController Apex includes a utility to clear the device programming and
reset certain items back to the factory default settings. This can be used to clear
the device when being used on a new system or to clear error conditions. Four
Initialize Memory functions are available: