![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 66](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298066.webp)
Apex Classic Setup and Programming Guide v2.2
Page
61
If Temp > RT+0.2 then OFF
This will turn the heater outlet on when the Temp probe measures the Regional
Temperature less .3 degrees. The heater outlet will turn off at Regional
Temperature plus .2 degrees.
The following command could be used to trigger an alarm:
If Temp > RT+2 Then ON
This will turn on the alarm when the aquarium temperature reaches 2 degrees
above the Regional Temperature set point.
SEASONAL LIGHTING ADJUSTMENT
The AquaController Apex can simulate the varying lengths of daylight during the
seasons of the year based upon a typical tropical reef at 15° north latitude. The If
Sun command is used to turn outlets on and off that automatically adjust to
these seasonal adjustments throughout the year. An offset from the standard
time is provided so multiple lights can be cycled on and off in sequence. The
following commands could be used to control a light on a system:
Light1:
If Sun 000/000 Then ON