![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298033.webp)
Apex Classic Setup and Programming Guide v2.2
Page
28
prone to errors as X10 communications can be. If X10 must be used, the X10
Control Interface (i.e. IM513) is plugged in to the Control port on the
AquaController Apex Base Module or in to the last legacy device in the Control
chain. All X10 addresses must be manually added to the Apex system. Blocks of
X10 addresses (i.e. B1 – B8) can be added by adding a DC4 or DC8 at the
appropriate starting X10 address and deleting any extra X10 outlets that are not
to be used. To add a DC4 or DC8, follow the instructions in the section titled
Adding Legacy Modules to the Apex System. To add a single X10 address follow
the instructions in the next section titled Adding Legacy Outlets.
WARNING: X10 connected devices can be unreliable and prone to noise
and environmental conditions. Users are urged to use EnergyBar or legacy
Direct Connect outlets with the AquaController Apex system to ensure the most
reliable control.
ADDING LEGACY OUTLETS
Follow the instructions in this section to add a single Legacy Outlet for use with
X10 modules or to be used as a Virtual Outlet. The X10 Outlet must be set to a
unique address in the system (it must not conflict with other legacy outlets on
the system).
To Add an X10 Outlet to the system:
Apex Display: Setup – Outlet Setup – Add Outlet – use the up/down
arrows to highlight the item to change:
Name: - use the up/down arrows to change the highlighted digit, use
the left/right arrows to select the highlighted digit, when done, press
OK.
Icon: - use the up/down arrows to select the icon to be displayed on
the Status Screens, when done, press OK.
Addr: - use the up/down arrows to select the X10 address configured
for this module.
When done, push Save to save changes and add the X10 Outlet.
Web Interface: This option is not available from the Web Interface.
DELETING LEGACY OUTLETS
Follow the instructions in this section to delete a single Legacy Outlet.
To Delete an X10 Outlet to the system: