![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298070.webp)
Apex Classic Setup and Programming Guide v2.2
Page
65
WARNING: Tunze recommends an intensity of 30% or higher for Tunze
Streams Pumps. For best results and longevity of your pumps, never set
the Minimum Intensity lower than 30%.
For example, assume the following settings:
Synchronize = off
Divide by 10 = off
Initial off time = 10
On time = 15
Off time = 20
Minimum Intensity = 30
Maximum Intensity = 70
Using this Profile, the pump will run at 30% for 10 seconds, 70% for 15 seconds,
30% for 20 seconds, 30% for 10 seconds, 70% for 15 seconds, 30% for 20
seconds, etc.
RAMP PROFILE TYPE
The Ramp Profile is used to ramp the port output voltage (up or down) from one
intensity to another over a period of time. It is typically used to ramp lights on of
off but can also be used with pumps to simulate varying intensity of tidal currents
for example.
Ramp Time: period in minutes over which the ramp should occur.
Start Intensity: the starting intensity in percent
End Intensity: the ending intensity in percent
EDITING PROFILES
Editing Profiles from the Apex Display
Edit the Profile name and Type
Setup – Profile Setup – Edit Type – use the up/down arrows to highlight the
Profile you wish to edit, press Select.
To edit the Profile Name, highlight Name: and push Select, use the up/down
arrow keys to change the character, use the left/right arrows to select the
digit to edit, press Select when done.
To Edit the Profile Type highlight Type: and push Select, use the up/down
arrow keys to toggle between Ramp and Pump, press Select when done.
Push Save to save or Exit to discard changes.
Edit Profile Settings