Apex Classic Setup and Programming Guide v2.2
Page
64
PUMP PROFILE TYPE
The Pump Profile is typically used to oscillate the speed of a pump from one
speed to a higher speed and back. Popular use of this feature is to create
resonant or chaotic waves in larger tanks depending on if the waves are
synchronized or not. The Pump Profile uses the Minimum Intensity setting to
specify the speed of the pump when set “off” by the Profile and the Maximum
Intensity setting to specify the speed of the pump when set “on” by the Profile.
When the pump is turned off by a line of program code like “If FeedA then OFF”,
the pump will be totally off (the Minimum Intensity setting is not used). The
pump Profile contains the following parameters:
Synchronize: when enabled, a port using this Profile will synchronize its Initial
Off time with the previous pump Profile (i.e. if enabled on Profile 2, it will sync
with Profile 1). Synchronize is useful for creating large waves through
constructive interference with pumps on either side of the tank.
Divide by 10: when enabled, all times in the Profile are divided by 10 (i.e. 56
seconds becomes 5.6 seconds).
Figure 7 - Profiles Setup Screen
Initial Off Time: when a pump with this Profile is first activated, it will be OFF
initially for this time (in seconds unless divide by 10 is enabled).
On Time: once the Initial Off Time expires, the pump will be ON for this amount
of time (in seconds unless divide by 10 is enabled).
Off Time: once the On Time expires, the pump will be OFF for this amount of
time (in seconds unless divide by 10 is enabled).
Minimum Intensity: the port output in percent when the pump is “off”
Maximum intensity: the port output in percent when the pump is “on”