Apex Classic Setup and Programming Guide v2.2
Page
47
Off time – the time the light should turn off in 24 hour format
(hours:minutes).
Shutdown probe – the name of the temperature probe that should be
monitored to shutdown the outlet in an overheating situation (Temp,
TempA, Tmpx3, etc).
Device shutdown value – the temperature that must be reached to turn off
the outlet.
Hysteresis – amount of time to leave the lights off (to prevent rapid cycling
of the outlet).
PUMP
This Wizard is used to program pumps or power heads to oscillate on and off.
Fallback – the state the outlet should switch to if contact between the
EnergyBar and base module is lost (on or off).
Initial Off Time – when this outlet first starts, this is the amount of time the
pump should be off before proceeding to the On Time (minutes:seconds).
On Time – after the Initial Off Time expires, this is the amount of time the
pump should be On before proceeding to the Off Time (minutes:seconds).
Off Time – after the On Time expires, this is the amount of time the pump
should be Off before proceeding to Initial Off Time (minutes:seconds).
Feed timer – the Feed Timer that should turn off this pump (A, B, C or D).
Feed timer delay – the time after the Feed Timer expires before starting the
pump back up.
HEATER
The Heater Wizard is used to program heater outlets. See the section titled Set
Points in the Programming with Hysteresis section for help in choosing on and off
set points. The settings for this Wizard are:
Fallback – the state the outlet should switch to if contact between the
EnergyBar and base module is lost (on or off).
Probe name – the name of the temperature probe that should be used to
control this outlet (Temp, TempA, Tmpx3, etc).
On temperature – the temperature at which the heater should turn On.
Off temperature – the temperature at which the heater should turn Off.
CHILLER
The Chiller Wizard is used to program chiller outlets. See the section titled Set
Points in the Programming with Hysteresis section for help in choosing on and off
set points. The settings for this Wizard are: