![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298035.webp)
Apex Classic Setup and Programming Guide v2.2
Page
30
PROBE EXPANSION PX-1000
The PX-1000 adds Temperature, pH and pH/ORP ports to the AquaController
system. It connects to the port labeled I/O on the Apex Base Module. Connect
Temperature, pH and ORP probes to the PX-1000 as needed. Power for the PX-
1000 is supplied by the included AC adapter. Only every 3
rd
PX-1000 needs a
power adapter. Before the Probe Expansion will be recognized, it needs to be
enabled on the Apex system as follows:
To enable/disable Probe Expansion:
Apex Display: System – Misc Setup – Probe Exp: Off – push the Select
button to toggle Probe Expansion on and off. The AquaController Apex must
be rebooted before this change takes effect. Either power cycle the Apex
Base Module (disconnect the AquaBus cable for 10 second and reconnect)
or see the section titled Restart the Apex (optional) for instructions on how
to restart the Apex.
Web Interface: This option is not available from the Web Interface.
Once the Probe Expansion is enabled, the PX-1000 should be automatically added
to the system. Up to 3 PX-1000 expansion modules can be daisy-chained
together off the I/O port. Each PX-1000 provides 6 digital inputs for float
switches, sensors, etc.
PX-1000 temperature, pH and ORP probes are enabled/disabled and calibrated
using the same menus and procedures as the Apex Base Module probes, see the
section titled Probe Setup for more information.
PROBE SETUP
The AquaController Apex system uses various probes to monitor your system.
The measurements from these probes can be displayed on the Apex Display
Module and Web Interface. The measurements from these probes can be used to
control your system and alert you of problems through email alerts or audible
alarms, see the section titled Programming Alarms and Warnings in the
Programming Outlets section for more information on setting up email alerts and
audible alarms.
TEMPERATURE PROBE SETUP
A port to connect a temperature probe is included on the Apex Base Module and
on several of the Apex system expansion modules. Setup and configuration of