Apex Classic Setup and Programming Guide v2.2
Page
99
SET
The Set command is used to set an outlet on or off.
Set = ON
In this example, if the outlet will be set on.
Syntax
Set Y
Y = ON to turn the outlet on or OFF to turn the outlet off
NOTE: Commands later in the outlet program may override this command. See
the section titled Order of Operation for more information.
APPENDIX 4 – ADVANCED PROGRAMMING EXAMPLES
DEFAULT PROGRAM
When an EnergyBar 8 or Direct Connect 8 is added to the system, the following
default program is added to each outlet:
Light 1 <Real Outlet 1>
Fallback Off
Set Off
If Time 08:00 to 20:00 Then ON
Light 2 <Real Outlet 2>
Fallback Off
Set Off
If Time 08:30 to 19:30 Then ON
Pump 1 <Real Outlet 3>
Fallback On
OSC 000:00/005:00/005:00 Then ON
If FeedA 000 Then OFF
Pump 2 <Real Outlet 4>
Fallback On
OSC 005:00/005:00/000:00 Then ON
If FeedA 000 Then OFF
Heater <Real Outlet 5>
Fallback Off
If Temp < 77.0 Then ON