![Neptune Systems AquaController Apex Classic Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/neptune-systems/aquacontroller-apex-classic/aquacontroller-apex-classic_setup-and-programming-manual_1668298028.webp)
Apex Classic Setup and Programming Guide v2.2
Page
23
many seconds to adjust the internal clock per day. For example if the clock is
gaining 1.5 seconds per day, a value of -1.5 would be entered to offset this
inaccuracy. The AquaController Apex uses this value to slow its time down by 1.5
seconds each day. To set the Leap Second adjustment
Apex Display: System – Clock Setup – Leap Second – use the up/down
arrows to set the Leap Seconds per day (either positive or negative leap
seconds), when done, press OK.
Web Interface: This option is not available from the Web Interface.
APEX MODULE SETUP
All Apex modules connect to the system through the AquaBus. Once connected,
they are automatically detected and added to the system configuration. All Apex
modules are upgraded using the steps and directions found in the section titled
Updating Firmware.
To connect a new Apex Module to the system, plug one end of the AquaBus cable
into an available AquaBus port on the system, and the other end into the new
Apex Module. Power and communication signals are passed through the AquaBus
to the new Apex Module. The order modules are connected is not important and
the AquaBus is plug and play meaning you do not need to power down the
system to connect a new module. The entire length of the AquaBus should be
kept to a maximum of 200 feet.
WARNING: NEVER plug standard USB devices into any AquaBus connector
or AquaBus accessories into computer USB ports. Damage to the AquaBus
accessory and/or USB device may result.
ENERGYBAR 8
AquaController Apex Energy Bar 8 (EB8) provides 6 solid state and 2 relay
controlled outlets to control typical 120V AC items such as lights, heaters,
chillers, etc. In addition, EB8 provides power to the other modules in the system
through the AquaBus. It includes a 6 port AquaBus hub for flexible configuration
options. EB8 outlets are programmed using the steps outlined in the section titled
Programming Outlets.
PROBE MODULE 1
AquaController Apex Probe Module 1 (PM1) adds a Temperature and pH/ORP
ports to the Apex system. This module connects anywhere on the AquaBus and
includes 2 AquaBus ports for flexible connection options. PM1 also includes 6