Apex Classic Setup and Programming Guide v2.2
Page
48
Fallback – the state the outlet should switch to if contact between the
EnergyBar and base module is lost (on or off).
Probe name – the name of the temperature probe that should be used to
control this outlet (Temp, TempA, Tmpx3, etc).
On temperature – the temperature at which the chiller should turn On.
Off temperature – the temperature at which the chiller should turn Off.
PH CONTROL
The pH Control Wizard is used to program the administration of additives that
alter the pH of your system. These can include CO2 in planted aquariums, control
of the pH inside calcium reactors, limiting Kalkwasser introduction or the
automated introduction of buffer solution. See the section titled Set Points in the
Programming with Hysteresis section for help in choosing high and low set points.
The settings for this Wizard are:
Fallback – the state the outlet should switch to if contact between the
EnergyBar and base module is lost (on or off).
Probe name – the name of the pH probe that should be used to control this
outlet (pH, pH1, pHA, pHB, pHx3, pHx4 etc).
High value – the high value at which the outlet is turned on or off (based
on the setting of On When).
Low value – the low value at which the outlet is turned on or off (based on
the setting of On When).
On when – when set to High, the outlet is On when the pH value is above
the High Value setting. When set to Low, the outlet is On when the pH
value is below the Low Value. (Low or High).
ORP CONTROL
The ORP Control Wizard is used to program the administration of additives that
alter the ORP level of your system, most commonly ozone. See the section titled
Set Points in the Programming with Hysteresis section for help in choosing high
and low set points. The settings for this Wizard are:
Fallback – the state the outlet should switch to if contact between the
EnergyBar and base module is lost (on or off).
Probe name – the name of the ORP probe that should be used to control
this outlet (ORP, ORPA, ORPB, ORPx3, ORPx4 etc).
High value – the high value at which the outlet is turned on or off (based
on the setting of On When).
Low value – the low value at which the outlet is turned on or off (based on
the setting of On When).