– 604 –
CHAPTER 5
Operation Procedure for System with PIR
3.2
TRUNK FAULT
This paragraph explains the fault repair procedure when a fault, shown in Table 5-3, has occurred to a spe-
cific trunk.
3.2.1
Check Point
When repairing a trunk fault, consider the following items:
(1) Check alarm lamps on trunk circuit cards.
(2) When an outgoing call cannot be originated to a specific trunk or when an incoming call cannot be
terminated from a specific trunk, check Tenant Restriction Data (assigned via ATNR command) and Route
Restriction Data (assigned via ARSC command).
(3) Three-Way Conference Trunk (CFT) is on the MUX (PH-PC36) circuit cards. If a three-way conference
call cannot be established, check the MUX cards.
(4) If the present timing for supervising the trunk/sender status is considered responsible for the fault, change
the timing. The specifications for timings that can be changed with respect to trunks and senders are shown
in Table 5-4 and Table 5-5.
Table 5-3 Trunk Fault Situation
TRUNK
FAULTY SITUATION
REFERENCE SECTION
ORT
No connection can be set up.
PB/DP signals are erroneously received or cannot be received.
Section 3.2.3, Trunk (ORT, SND,
CFT) Fault
SND
No connections can be set up.
PB/DP signals are erroneously sent out or cannot be sent out.
CFT
No connections can be set up.
No three-way calling can be made.
Noise gets in an established connection.
COT
TLT
DTI
No connections can be set up.
A connection results in no speech.
Noise gets in an established connection.
Section 3.2.4, Trunk (COT, TLT,
DTI) Fault
MG
No connections can be set up.
A connection results in no speech.
Noise gets in an established connection.
Refer to the Installation and startup
procedure of MG (Media Gateway)
in Peripheral Equipment Manual.
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......