– 528 –
CHAPTER 4
Fault Repair Procedures
1. IP RELATED FAULT AND ITS REASON
Because of the system characteristic, there will be faults related to system side equipment and other faults
(including the fault occurred on the network). Refer to system message and detailed data for the best treatment.
In a certain condition, alarm may not be released or the failure may not be solved by the operation of procedure
below.
IP Related Fault and Its Reason
Fault Message
Reasons to be fixed
Reference
33-R
FNC=02H, INF=04H, FLT=04H
(Exceeding maximum number of connection)
• Connection unavailable
FNC=05H (Sequence Error), INF=01/02H,
FLT=xxH
• Initializing fault for IPPAD circuit
card
• Fault in IP station while processing
registration
FNC=03H, INF=01H, FLT=02H
(Excessive loss of RTP packets)
• Occurrence of packet loss
• Voice cut-off or sudden-mute
• IPPAD circuit card failure
FNC=05H, INF=01H, FLT=02H
(Command re-sending Error)
• Communication unavailable
33-S
FNC=02H, INF=01H
(Ethernet (LAN) cable not plugged-in)
• Link down of Ethernet (LAN) cable
in front panel of IPPAD circuit card
FNC=05H (Sequence Error), INF=01/02H,
FLT=xxH
• Initializing fault for IPPAD circuit
card
• Fault in IP station while processing
the registry
FNC=05H, INF=04G, FLT=02H
(Command re-sending Error)
• Communication unavailable
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......