– 348 –
CHAPTER 3
System Messages
7-V:
PLO MB Key Turn OFF
This message displays when the MB switch on the PLO card is turned off while extracting or inserting a circuit
card
.
Faulty PLO card number
Status of PLO card at the time of
failure detection (Scan Data 1)
Status of PLO card at the time of
failure detection (Scan Data 2)
Default Alarm
Default Grade
Grade Modified
Lamp Modified
NON
3
1:
XXXX
XX00
0000
0000
2:
0000
0000
0000
0000
3:
0000
0000
0000
0000
4:
0000
0000
0000
0000
5:
0000
0000
0000
0000
6:
0000
0000
0000
0000
7:
0000
0000
0000
0000
8:
0000
0000
0000
0000
9:
0000
0000
0000
0000
b7
b0
b7
b6
b5
b4
b3
b2
b1
b0
b7
b4
b1
b0
1 2
3
b0:
0/1 = PLO System 0/PLO System 1
1
b0:
0/1 = Clock STBY/ACT
b1:
0/1 = PLO Synchronizing/PLO self-running or drifting
b2:
0/1 = -/Input clock down
b3, b4: Route of Input clock (see table)
b5:
0/1 = -/PLO input all down
b6:
0/1 = -/PLO output down
b7:
0/1 = -/Drifting
b4 b3
CONNECTIED WITH PRIMARY
OSCILLATOR (M-OSC)
CONNECTED WITH
EXTERNAL CLOCK
0
0
M-OSC 0
Route 0
0
1
M-OSC 1
Route 1
1
0
-
Route 2
1
1
-
Route 3
2
b0:
0/1 = -/n
u
five millisecond clock down
b1:
0/1 = -/Frame Synchronization down from SYNC card
b4:
0/1 = -/Internal OSC clock down
3
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...