Operations of SV8500 Server
The relationship of operation types and Initialization types is as follows.
Figure 2-2 Office Data Load and Program Load
3.2 Initialization by PCPro (SINZ)
All initialization types shown below are available.
•
Non Load Initial
•
Office Data Load Initial
•
Office Data Load & Program Load Initial
•
Office Data Load & Program Load (& OS Load) Initial
Note:
Use shutdown option on SINZ command.
STEP 1
Execute SINZ from the PCPro.
STEP 2
Select an appropriate initialization type, and then click “Execute” button.
•
Initialization starts.
•
PCPro is automatically placed in logout state.
Relationship between Initialization Types and Available Operations
X: Available -: Not Available
Initialization Type
Available Operations
PCPro
(SINZ)
PCPro
Tools
INIT key Operation
(EMA card)
Tuning Off/On
Non Load Initial
X
-
X
-
L
o
ad Initia
l
Office Data Load Initial
X
-
-
-
Office Data Load & Program Load Initial
X
-
-
-
Office Data Load & Program Load (& OS Load) Initial
X
X
-
X
CF Card
Program
(Main Memory)
Office Data
- Basic Software
- Service Software
- IMAT Software
- TCP/IP Software
- Data Memory
- Call Forwarding Data
- Speed Calling Data
- Name Display Data
etc.
MEM
- Program
- Office Data
Program Loading
Office Data Loading
Initialization
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......