– 658 –
CHAPTER 5
Operation Procedure for System with PIR
4.13.3 Specific DCH/PRT Card Is Faulty
(1) Check by replacing the DCH/PRT card with a spare.
(a) On DCH/PRT card, set MBR switch UP.
(b) On DCH/PRT card, set MB switch UP and extract the card from its mounting slot.
(c) Make switch setting on a new DCH/PRT card.
(d) On new DCH/PRT card, set MBR and MB switches UP and insert the card into its mounting slot.
(e) On new DCH/PRT card, set MB switch DOWN.
(f)
On new DCH/PRT card, set MBR switch DOWN.
(g) Check whether the fault is still indicated.
4.13.4 Fault of DCH, DTI, and Related Flat Cable
(1) Check the connectors and flat cables between DTI and DCH.
[Check the connector.]
(a) On DTI cards, set MB switch UP. On DCH card, set MBR switch UP.
(b) Check whether the connector is correctly connected. If the connection is found improper, plug and un-
plug the connector a few times.
(c) On DTI cards, set MB switch DOWN. On DCH card, set MBR switch DOWN.
(d) Check whether the fault is still indicated.
[Check the flat cable.]
(a) On DTI cards, set MB switch UP. On DCH card, set MBR switch UP.
(b) Test the continuity of the flat cable. If abnormal, replace the flat cable with spare.
(c) On DTI cards, set MB switch DOWN. On DCH card, set MBR switch DOWN.
(d) Check whether the fault is still indicated.
(2) Check by replacing the DTI card with a spare.
(a) On DTI card, set MB switch UP and extract the card from the mounting slot.
(b) On a new DTI card, make switch setting.
(c) On new DTI card, set MB switch UP and insert the card into the mounting slot.
(d) On new DTI card, set MB switch DOWN.
(e) Check whether the fault is still indicated.
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......