– 900 –
CHAPTER 7
Maintenance Commands
RLST: Release Station/Trunk
1. Functional Outline
This command is used to release a station, trunk, or virtual trunk when using PHG circuit card.
When in-progress virtual trunk is not able to recover from a fault, this command is used to disconnect the in-
progress call forcefully due to the recovery.
2. Parameters
Input data
TYPE: Type of Select (1-5)
1=Stations
2=Trunk
3=LENS
4=Connection Trunk
5=Virtual Trunk
TN: Tenant Number
STN: Station Number (maximum six digits)
TK: Trunk Number
LENS: Line Equipment Number
Connection RT: Connection Route Number (1-1023)
Connection TK: Connection Trunk Number (1-4095)
Note 1:
This option is valid when assigning 1 or 2 on CDN68: VIR by the ART command, indicating that the
WAN or MG connections are specified as virtual trunk identification data.
Note 2:
This parameter is valid only when TYPE=1.
Note 3:
This parameter is valid only when TYPE=2.
Note 4:
This parameter is valid only when TYPE=3.
Note 5:
This parameter is valid only when TYPE=4.
Output data
STATUS: Status of Station/Trunk (1-4)
0=Not Assigned
1=Idle
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......