– 559 –
CHAPTER 5
Operation Procedure for System with PIR
STEP 3
Turn ON (upward) the TSW MBR key on the TSW card of STBY side.
TSW ACT (TSW card) = lit (red)
MUX ACT (MUX card) = off
STEP 4
Is PLOACT lamp of TSW card (STBY side) to be replaced lit (green)?
YES: Turn ON (upward) the PLO MB key on the TSW card to be replaced.
PLO ACT is changed over. PLOACT lamp on the TSW card goes out.
STEP 5
Turn ON (upward) the MB key on the TSW card.
•
M0SY lamp (TSW card) = off
•
SYNC lamp (MUX card) = off
STEP 6
Turn ON (upward) the MB key on the MUX card to be replaced.
STEP 7
Disconnect the cable from the connector on the front panel of the MUX card to be replaced.
STEP 8
Extract the MUX card to be replaced from the PIR.
STEP 9
Turn ON (upward) the MB key on the new MUX card.
STEP 10 Set the keys on the new MUX card, referring to the card replaced.
STEP 11 Insert the new MUX card into the PIR.
STEP 12 Connect the disconnected cable to the connector on the front panel of the new MUX card.
STEP 13 Turn OFF (down) the MB key on the TSW card.
STEP 14 Make sure M1SY/M2SY/M3SY LED, which corresponds to the new card, lights green on the
TSW card (PIR 0).
•
TSWACT lamp (TSW card) = lit (red)
•
M0SY lamp (TSW card) = lit (green)
•
SYNC lamp (MUX card) = lit (green)
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......