![background image](http://html1.mh-extra.com/html/nec/sv8500/sv8500_operation-and-maintenance-manual_3911915968.webp)
– 921 –
APPENDIX A
STEP 8
In PCPro Tools’ Patch menu:
1. Select the following:
• Operation:
Write
• Install Data Name:
Data selected in STEP 3–1
• Patch Selection:
Data Name set in “Install Data Name” box of STEP 5–2
2. Press “Execute” button.
(2) Use XPAT command to apply uploaded patch files to the Telephony Server.
STEP 1
Start up XPAT command.
STEP 2
Select target Telephony Server side to apply patches using radio buttons in “Mode: ACT/ST-
BY.”
STEP 3
Press “Get” button to display “Patch Information List” (list of uploaded patch files).
• When application for all uploaded patch files have been completed:
Message “Everything has been applied.” appears.
Press “Exit” button to end XPAT command.
STEP 4
Press “Check” button to check formats for patch files.
• When all files are in correct format:
“Apply” button becomes active.
• When an incorrect file format exists:
Error message is displayed in “Check Result” column of “Patch Information List.”
“Apply” button does not become active.
STEP 5
Press “Apply” button.
Message “Do you apply patch?” appears.
Press “OK” to start applying the patch.
• When all patch file application was successful:
Message “Patch application success. Display information is updated.” appears.
• When patch application failed:
Message “Patch application failed. Display information is updated.” appears.
Note 1:
Pressing the “OK” button automatically executes readout to update the Patch Information List. When
patch application failed, the first patch file in “Applied Status” column displayed as “Unapplication”
failed to have the patch applied. Contact the patch provider when this problem occurs.
STEP 6
Press “Exit” button to end XPAT command when patch application is complete.
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......