– 538 –
CHAPTER 4
Fault Repair Procedures
About System Message “33-R” Outputted From Internal PHC
(1) FNC=
02H
, INF=
04H
, FLT=
04H
(Exceed number of maximum connection) is outputted
Fault reason
•
Connection is not available
•
Exceeding the maximum number of connection allowed
<<Unable to originate or terminate any calls using PHC>>
PHC office-to-office connection is operated with exceeding the maximum number of connections al-
lowed.
(a) Confirm the maximum number of connection allowed, and whether trying to establish a number of
connection exceeding that number or not.
(b) If operating normally after the confirmation, it is simply a matter of maximum numbers. Continue
monitoring.
Note:
System Message about exceeding of maximum number is outputted from internal PHC. Confirm the max-
imum numbers of connection allowed.
•
Maximum of 48 IPTRK (CCIS) is available.
•
Internal PHC (CCIS) can handle up to 64.
(c) problem is still not solved after performing this procedure.
About System Message “33-R” Outputted From Internal PHI
(1) FNC=
05H
, INF=
04H
, FLT=
02H
(Command re-send error) is outputted
Fault reason
•
Unable to reply
<<This System Message will be output when control packet send timer time out has occurred eight times
continuously or when any communication fault was detected while sending the control packet.>>
Cause of the error may be the hardware fault or network interference.
(a) Confirm the operating status of MG (Media Gateway).
(b) Confirm each network equipment, connection and configuration when this fault occurs frequently.
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......