– 603 –
CHAPTER 5
Operation Procedure for System with PIR
3.1.7
Line fault - Dterm
[1] When using LC/ELC circuit card.
Note:
If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used
until the replacement is complete.
Note:
If any of the in-house cable wirings short-circuit, the POW ALM lamp on the ELC circuit card lights.
Remove the cause of the short-circuit and initialize the ELC circuit card.
(1) When OPE lamp on the ELC circuit card does not illuminate.
(a) Confirm that MB switch of the ELC circuit card is not in ON position (UP).
(b) Confirm that station data (ASDT command) in the ELC circuit card is assigned.
(c) Replace ELC circuit card with a spare.
(2) When BL lamp for each line is flashing or illuminating on the ELC circuit card.
(a) Confirm that MB switch of the ELC circuit card is not in ON position (UP).
(b) Use the MBST command to confirm that ELC circuit card has not been placed into make-busy state.
(c) Check the station data (ASDT command) assignment.
(d) Replace the ELC circuit card with a spare.
(3) Check the faulty line on the MDF.
(a) Isolate the faulty line to the in-house wiring side and to the system side.
(b) Connect the test Dterm to the system side.
(c) Confirm speech by station-to-station calling.
[When speech cannot be made]
•
Check LT cables.
•
Replace ELC circuit card with a spare.
[When speech can be made]
•
Check to see if the modular plug is firmly connected with the Dterm.
•
Check the wiring inside the rosette.
•
Check the in-house wiring for any abnormality.
•
Replace the Dterm with a spare.
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......