– 53 –
CHAPTER 2
Operations of SV8500 Server
4. ROUTINE DIAGNOSIS
For confirming its own servicing status, the system automatically executes self diagnosis every day, and
displays the result of the diagnosis as a system message. By this function, possible causes for trouble can be
discovered in an early stage and possible trouble can be prevented from remaining undetected.
4.1
Related System Data
•
ASYD, SYS1, INDEX86,
b0 –
When routine diagnosis starts, and the result of the routine diagnosis is normal, the result
displays as System Message [
0/1: Not displayed/Displayed
b1 –
When the result of the routine diagnosis is abnormal, it displays as System Message [
].
0/1: Not displayed/To display
b3, b2 –
Processing at the time when Trunk Ineffective Hold is detected.
Note 1
Note 1:
Trunk Ineffective Hold is a continuous state other than idle state within a predetermined duration while
routine diagnosis is in progress. Whether it is detected/not detected, it is assigned by ASYD, SYS1, IN-
DEX 89.
Note 2:
When Trunk Ineffective Hold on the FCCS Network is detected, setting of ASYD, SYS1, INDEX 86,
b2·b3 and SYS1, INDEX 89, b4·b5 must be the same at all nodes on the network.
•
SYS1, INDEX 87, 88 - Routine Diagnosis Start Time
Start time should be such a time which the traffic of the office is the lowest.
To stop the routine diagnosis, set FF respectively to INDEX87, 88.
BIT
The trunks being held at present are forcibly
released, except the trunks being held on two-
way calls (station-to-station call, station-to-
trunk, external trunk-to-external trunk call).
All trunks being held at
the present are forcibly
released
LENS of the trunk detected
display as System Message
[
b3
b2
0
0
X
—
X
0
1
—
—
X
1
0
—
X
X
INDEX 87
0
2
(Hour)
2:00 a.m. is the start time.
INDEX 88
0
0
(Minute)
Содержание SV8500
Страница 303: ...256 CHAPTER 3 System Messages Related call release result b7 b0 b7 0 1 Released Not released 4...
Страница 376: ...329 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 378: ...331 CHAPTER 3 System Messages Level Level b7 b6 b5 b4 b3 b2 b1 b0 G0 G1 G2 G3 G30 G31 0 1 Ineffectively held...
Страница 547: ...500 CHAPTER 3 System Messages IP Address of when failed to LOGIN b7 b6 b5 b4 b3 b2 b1 b0 16 19...
Страница 597: ...550 CHAPTER 4 Fault Repair Procedures This page is for your notes...
Страница 728: ...681 CHAPTER 6 Routine Maintenance Procedure Condition And Cause Procedure and Parts Used...
Страница 748: ...701 CHAPTER 7 Maintenance Commands SYSTEM SELECT 3 SW 1 8 Not used STS OFF Fixed...
Страница 781: ...734 CHAPTER 7 Maintenance Commands Exit Exit the command Clear Clear the values Recalc Re calculate bandwidth data...
Страница 798: ...751 CHAPTER 7 Maintenance Commands Set Execute the assigned MW lamp control Exit Exit this command...
Страница 843: ...796 CHAPTER 7 Maintenance Commands Get Get the Individual Call Block Data Exit Exit this command...
Страница 973: ......
Страница 974: ...Printed in Japan 0901 020...
Страница 975: ......