7-6 Troubleshooting
On-screen error message
Cause
Action
0B96 BMC SDR Repository
failure
SDR repository within BMC
is faulty.
0B97 BMC SEL device failure
SEL repository within BMC is
faulty.
0B98 BMC RAM test error
BMC RAM is faulty.
0B99 BMC Fatal hardware
error
BMC FPGA is faulty.
0B9A BMC not responding
BMC device is faulty.
Replace the CPU/IO module.
0B9B Private I2C bus not
responding
I2C bus is faulty.
If turning AC power off and on
does not help, replace the
CPU/IO module or the system
backboard.
0B9C BMC internal exception
0B9D BMC A/D timeout error
BMC device is faulty.
Replace the CPU/IO module
0B9E SDR repository corrupt
SDR data is faulty.
If updating SDR does not solve
the issue, replace the CPU/IO
module.
0B9F SEL corrupt
SEL repository within BMC is
faulty.
Replace the CPU/IO module
0BA0 SDR/PIA mismatched.
SDR, PIA must be
updated.
SDR and PIA data do not
match.
If updating SDR/PIA does not
solve the issue, replace the
CPU/IO module.
0BB0 SMBIOS - SROM data
read error
•
I2C bus is faulty.
•
SROM is faulty.
•
BMC is faulty.
0BB1 SMBIOS - SROM data
checksum bad
Data within SROM is faulty.
If turning AC power off and on
does not help, replace the system
backboard.
0BC0 POST detected startup
failure of 1st Processor
CPU is faulty.
0BC1 POST detected startup
failure of 2nd Processor
Replace the CPU.
8100 Memory Error detected
in DIMM group #1
Replace DIMM slot 1 and 2.
8101 Memory Error detected
in DIMM group #2
Replace DIMM slot 3 and 4.
8102 Memory Error detected
in DIMM group #3
Replace DIMM slot 5 and 6.
8103 Memory Error detected
in DIMM group #4
Replace DIMM slot 7 and 8.
8104 Memory Error detected
in DIMM group #5
Replace DIMM slot 9 and 10.
8105 Memory Error detected
in DIMM group #6
DIMM is faulty.
Replace DIMM slot 11 and 12.
8120 Unsupported DIMM
detected in DIMM
group #1
8121 Unsupported DIMM
detected in DIMM
group #2
Non-supported DIMM is
mounted.
Check the supported DIMM and
replace the DIMM. If replacing the
DIMM does not help, replace
CPU/IO module.
Содержание N8800-162F
Страница 10: ...this page is intentionally left blank...
Страница 43: ...General Description 2 7 Front View With front bezel attached With front bezel removed...
Страница 46: ...2 10 General Description Rear View R320a E4 R320b M4...
Страница 49: ...General Description 2 13 CPU IO Module 1 PCI Riser card R320a E4 top cover removed R320b M4 top cover removed...
Страница 90: ...3 22 Linux Setup and Operation This page is intentionally left blank...
Страница 107: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Страница 124: ...4 34 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Страница 136: ...4 46 System Configuration This page is intentionally left blank...
Страница 162: ...5 26 Installing and Using Utilities DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 212: ...6 16 Maintenance This page is intentionally left blank...
Страница 236: ...7 24 Troubleshooting This page is intentionally left blank...
Страница 267: ...System Upgrade 8 31 PCI 2 PCI 1 R320a E4 R320b M4 PCI 2 PCI 1 PCI 4 PCI 3 Riser Card...