5-42 Installing and Using Utilities
Check and Clear of MTBF Information
The MTBF information of a component can be viewed or cleared (initialized).
NEC Express5800/ft series manages the MTBF (mean time between failure) of each component. If
a fault occurs in a component, the NEC Express5800/ft series calculates the MTBF of the
component again. If the calculated value is lower than the pre-defined threshold, the NEC
Express5800/ft series disables the component to be used.
Contact your maintenance personnel if such a symptom as above occurs.
The table below shows in which Fault Class a component can check.
Check of MTBF Information
Component
Remote Local
CPU Module
Fault Class:
uncorrectable
Fault Class:
correctable
uncorrectable
microsync
*
* The current version
does not support it.
PCI Module
Fault Class:
uncorrectable
Fault Class:
uncorrectable
Remote:
Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using ft server utility
–: Not
support
IMPORTANT:
A disabled component with the MTBF lower than the threshold can be
forcibly enabled by clearing the MTBF. However, contact your maintenance personnel for the
forced use of such a component.
To clear the MTBF information of a component with NEC ESMPRO Manager, use the
[Maintenance] tree of the component of the [ft] tree of the DataViewer. Open the tree of the
component whose MTBF information is to be cleared and select the [Maintenance] tree.
To clear the MTBF information of a component with the ft server utility, use the utility screen of the
component. The table below shows the potential cases in which the MTBF information of a
component is to be cleared. Contact your maintenance personnel for clearing MTBF information.
MTBF clear
Component
Remote Local
CPU Module
To start the module forcibly after
replacing a module or if MTBF became
lower than the threshold due to
malfunction and disabled the module.
Executable in the following module
state (this can be viewed on manager
screen):
•
Broken
MTBF is lower than the threshold.
To start the module forcibly after replacing
a module or if MTBF became lower than
the threshold due to malfunction and
disabled the module.
Executable in the following module state:
•
The amber LED is on.
•
The event indicating that MTBF is lower
than the threshold is registered in the
event log.
PCI Module
Same as above
Same as above
Remote:
Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using ft server utility
–:
Not
support
Содержание N8800-162F
Страница 10: ...this page is intentionally left blank...
Страница 43: ...General Description 2 7 Front View With front bezel attached With front bezel removed...
Страница 46: ...2 10 General Description Rear View R320a E4 R320b M4...
Страница 49: ...General Description 2 13 CPU IO Module 1 PCI Riser card R320a E4 top cover removed R320b M4 top cover removed...
Страница 90: ...3 22 Linux Setup and Operation This page is intentionally left blank...
Страница 107: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Страница 124: ...4 34 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Страница 136: ...4 46 System Configuration This page is intentionally left blank...
Страница 162: ...5 26 Installing and Using Utilities DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 212: ...6 16 Maintenance This page is intentionally left blank...
Страница 236: ...7 24 Troubleshooting This page is intentionally left blank...
Страница 267: ...System Upgrade 8 31 PCI 2 PCI 1 R320a E4 R320b M4 PCI 2 PCI 1 PCI 4 PCI 3 Riser Card...