Linux Setup and Operation 3-5
Restoring the redundant configuration manually
This section provides information on how to replace a failing internal disk and restore duplication.
IMPORTANT:
This must be operated by root user.
While the replaced disk is restoring to the RAID configuration, do not stop/restart the system
when the reconfigured each RAID device is in RECOVERY. Wait until their status turns to
DUPLEX. Note that the wait time is proportional to the disk volume.
1.
In the command prompt of ftdiskadm, select [Remove Half Disk (RAID1)
]
to specify the
slot number of the internal disk to replace, and isolate the disk from the RAID
configuration.
2.
Remove the disk from the system, and then, insert a new disk.
3.
Wait approximately five minutes until the system automatically performs
resynchronization.
4.
If the system does not perform resynchronization automatically in step 3, recover RAID
manually by selecting [Repair Mirroring Arrays (RAID1)] in ftdiskadm.
The following is an example of command prompt for the procedure from isolating the internal disk
stored in the slot 9 (PCI module 1 - Slot 0) through restoring redundancy.
# ftdiskadm
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
(RAID1)
4 Repair Mirroring Arrays
(RAID1)
5 Delete Mirroring Arrays
(RAID1)
6 Remove Disk Partitions
(RAID1)
7 Make Striping Array
(RAID1+0)
8 Delete Striping Array
(RAID1+0)
c Configurations
q Quit
Command: 6 (Isolate the disk specified with the slot number from
the RAID configuration.)
[Remove Disk Partitions (RAID1)]
* Which SCSI SLOT? [1-16] 9
mdadm: hot
removed /dev/sdi5
mdadm: hot
removed /dev/sdi3
mdadm: hot
removed /dev/sdi2
mdadm: hot
removed /dev/sdi1
Command action
1 List RAID Arrays
2 List Internal Disks
3 Make Mirroring Arrays
(RAID1)
Содержание N8800-162F
Страница 10: ...this page is intentionally left blank...
Страница 43: ...General Description 2 7 Front View With front bezel attached With front bezel removed...
Страница 46: ...2 10 General Description Rear View R320a E4 R320b M4...
Страница 49: ...General Description 2 13 CPU IO Module 1 PCI Riser card R320a E4 top cover removed R320b M4 top cover removed...
Страница 90: ...3 22 Linux Setup and Operation This page is intentionally left blank...
Страница 107: ...System Configuration 4 17 Security Move the cursor onto Security to display the Security menu...
Страница 124: ...4 34 System Configuration Exit Move the cursor onto Exit to display the Exit menu...
Страница 136: ...4 46 System Configuration This page is intentionally left blank...
Страница 162: ...5 26 Installing and Using Utilities DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 212: ...6 16 Maintenance This page is intentionally left blank...
Страница 236: ...7 24 Troubleshooting This page is intentionally left blank...
Страница 267: ...System Upgrade 8 31 PCI 2 PCI 1 R320a E4 R320b M4 PCI 2 PCI 1 PCI 4 PCI 3 Riser Card...