8-48 Troubleshooting
Problems with Windows Server 2003 R2
There are some cases that an event log is registered as follows when you operate Windows
Server 2003 R2.
Source:
IPMIDRV
Type:
Error
Event ID:
1001
Description: The IPMI device driver attempted to determine if the system supported an
IPMI BMC device. The driver attempted to detect the presence of the IPMI
BMC by searching the SMBIOS for Type 38 record. But either no record was
found or the record was not compatible with the version of the device driver.
If a SMBIOS Type 38 record was detected, the Dump Data field of the event
contains a binary representation of the record.
→
If you use "Hardware Management" which is provided by Windows Server 2003
R2, above-shown event log will be registered.
For more details, refer to "Enabling the Hardware Management Feature bundled in
Windows Server 2003 R2" on the following site.
[NEC Express5800 Web Site]
http://www.nec.co.jp/express/download/W2K3_R2
Problems with Windows Server 2003
Cannot install the operating system correctly.
T
Did you confirm the notes on installing the operating system?
→
See Chapter 6.
Fail to start the OS:
T
Is a floppy disk in the floppy disk drive?
→
Take out the floppy disk and restart the server.
T
Is the NEC EXPRESSBUILDER CD-ROM in the DVD-ROM drive?
→
Take out the NEC EXPRESSBUILDER CD-ROM and restart the server.
T
Is the OS broken?
→
Use recovery process to recover the system.
Содержание N8100-1223F
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 10: ...This page is intentionally left blank...
Страница 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Страница 294: ...7 12 Maintenance This page is intentionally left blank...