SELECTING A SITE
Read the following precautions before selecting a suitable site for your server. The following
describes installation of the server and connections to the server.
CAUTION
Observe the following instructions to use the server safely. Failure to follow
these instructions may cause a fire, personal injury, or property damage. See
pages 1-3 to 1-8 for details.
■
Never attempt to lift the server with three or less persons.
■
Do not install the server in any place other than specified.
The following figure illustrates a site suitable for installing the server.
When you have selected a server site, hold the server by its bottom with at least four persons and
carry it to the site, then place it slowly and gently.
IMPORTANT:
Do not hold the server by its front door to lift the
server. The front door may be disengaged and damage the server.
* It is recommended that the server should be used in a room where
temperature is in the range between 15 to 25ºC.
Close enough to
connect the mouse
and the display.
Install the server on the
floor or rigid, flat desk.
Clean and tidy room
Place having a space enough to fully
open the front door (The front door
extrudes about 35 mm from the left
side of the server when fully opened.)
Room that satisfies the following
conditions for operation: *
Temperature: 10 to 35ºC
Humidity: 20 to 80% (no
condensation)
100 to 120 Vac/200 to
240 Vac parallel bi-polar
wall power outlet with
the ground line.
Wall outlet to connect the
supplied power cord.
Place having available space
of 150 mm or more in front
and rear of the server.
Содержание N8100-1223F
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 10: ...This page is intentionally left blank...
Страница 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Страница 294: ...7 12 Maintenance This page is intentionally left blank...