Troubleshooting 8-59
Error Message for Battery for On-board RAID (MegaRAID ROMB)
The battery is discharged and charged in a regular basis (every 30 days by the default). The
following error message may be registered in event log (application log), however, it is not a
problem in operating the system.
MegaRAID Storage Manager (MSM) log
Controller ID:x Battery is discharging.
Application event log
Event Source: MR_MONITOR
Event Type:
Warning
Event ID:
148
Description: Controller ID:x Battery is discharging.
MegaRAID Storage Manager (MSM) log
Controller ID:x BBU disables; changing WB logical drives to WT.
Application event log
Event Source: MR_MONITOR
Event Type:
Warning
Event ID:
195
Description: Controller ID:x BBU disables; changing WB logical drives to WT.
The battery is charged and discharged when it is replaced. The following error message may be
registered in event log (application log), however, it is not a problem in operating the system.
MegaRAID Storage Manager (MSM) log
Controller ID:x Battery requires reconditioning – please initiate a LEARN cycle.
Application event log
Event Source: MR_MONITOR
Event Type:
Warning
Event ID:
253
Description: Controller ID:x Battery requires reconditioning – please initiate a LEARN
cycle.
Содержание N8100-1223F
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 10: ...This page is intentionally left blank...
Страница 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Страница 294: ...7 12 Maintenance This page is intentionally left blank...