4-26 Configuring Your Server
Option
Parameter
Description
Your Setting
Boot
Monitoring
[Disabled]
5 minutes
10 minutes
15 minutes
20 minutes
25 minutes
30 minutes
35 minutes
40 minutes
45 minutes
50 minutes
55 minutes
60 minutes
Indicates whether the boot monitoring
function is enabled or disabled on booting.
To use this function, install NEC ESMPRO
Agent. Do not use this function if the system
is booted from OS without installation of NEC
ESMPRO Agent or CD-ROM. Set this item to
"Disabled" if ARCServe uses the Disaster
Recovery Option.
Boot
Monitoring
Policy
[Retry 3 Times]
Retry Service Boot
Always Retest
Appears when the boot monitoring feature is
enabled. This item indicates the processing
at the occurrence of timeout during boot
monitoring.
If [Retry 3 times] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried up to three times. The failure in
the third boot causes the boot to be tried from
the service partition.
If [Retry Service Boot] is selected, the system
is reset after the occurrence of timeout and
OS boot is retried up to three times. Then the
boot is tried from the service partition for
three times.
If [Always Reset] is selected, the system is
reset after the occurrence of timeout and OS
boot is retried repeatedly.
Thermal
Sensor
Disabled
[Enabled]
Indicates whether the temperature sensor
monitoring function is enabled or disabled.
BMC IRQ
Disabled
[IRQ 11]
Indicates the IRQ of the BMC interrupt.
Post Error
Pause
Disabled
[Enabled]
Indicates whether POST is aborted once at
the end of POST if an error occurs during the
execution of POST.
AC-LINK
Stay Off
[Last State]
Power On
Indicates the AC-LINK function. Shows the
state of the power of the server.
Power ON
Delay Time
[0] - 255
Sets the power on delay time when "Power
On" or "Last State" is specified for AC LINK.
FRU LED
Feature
Disabled
[Enabled]
Select "Enabled" to turn on the error lamp to
identify the location if the system detects a
failure.
Clear FRU
LED
[No]
Yes
Select "Yes" to turn off the FRU LED. When
the faulty component is replaced, turn off the
FRU LED.
Platform
Event
Filtering
Disabled
[Enabled]
Enables or disables the Platform Event
Filtering feature of the baseboard
management controller (BMC).
[ ]: Factory-set
Содержание N8100-1223F
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 10: ...This page is intentionally left blank...
Страница 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...