Troubleshooting 8-25
Error
code
Error message
Recommended Action
81A0
Cache Cautionary status detected on
Processor 1.
81A1
Cache Cautionary status detected on
Processor 2.
81A2
Cache Cautionary status detected on
Processor 3.
81A3
Cache Cautionary status detected on
Processor 4.
This is not a fatal error. Turn off the power once
and then on again to restart the server. If the
error cannot be corrected, contact your service
representative.
8200
Online Spare Memory was not ready.
DIMM type mismatch is detected when the
online spare memory feature is enabled.
Contact your service representative.
8201
Mirroring Memory was not ready.
DIMM type mismatch is detected or
unnecessary installation in group #2 is detected
when the memory mirroring feature is enabled.
Check the DIMM type or installation. If the error
cannot be corrected, contact your service
representative.
8202
Memory RAID was not ready.
Check if capacity, type, and installation status of
all DIMMs are correct.
8300
Secondary BIOS is corrupted.
Contact your service representative.
8400
Onboard PCIE#1 Link Failure
8401
Onboard PCIE#2 Link Failure
8412
PCI Slot#3 PCIE Link Failure
8413
PCI Slot#4 PCIE Link Failure
8414
PCI Slot#5 PCIE Link Failure
Turn off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service representative.
8420
Onboard PCIE#1 Link Width Error
8421
Onboard PCIE#2 Link Width Error
8432
PCI Slot#3 PCIE Link Width Error
8433
PCI Slot#4 PCIE Link Width Error
8434
PCI Slot#5 PCIE Link Width Error
This is not a fatal error, but performance may be
reduced. Turn off the power once and then on
again to restart the server. If the error cannot be
corrected, contact your service representative.
Other POST Errors
The following message does not appear on the screen, however, it is recorded in the system event
log.
Error code
Description
Recommended Action
8301
A BIOS Checksum error was detected in the
early stage of BIOS boot-up (Bootblock). The
control was transferred to the secondary BIOS.
(See Chapter 2 "Recovering BIOS Data".)
Contact your service
representative.
Содержание N8100-1223F
Страница 6: ......
Страница 7: ......
Страница 8: ......
Страница 10: ...This page is intentionally left blank...
Страница 36: ...1 16 Notes on Using Your Server This page is intentionally left blank...
Страница 171: ...Configuring Your Server 4 83 3 Setting menu for VD 0 is displayed...
Страница 294: ...7 12 Maintenance This page is intentionally left blank...