Configuring Your Server 4-41
Hot-swap rebuild
Automatic rebuild by hot-swapping defected HDD.
IMPORTANT:
Note the following for the rebuild:
The HDD used for rebuild should have the same capacity, rotation
speed, and standard as the defected HDD.
During rebuild, the processing rate is decreased due to much load.
During rebuild, do not shutdown or reboot the server. If the server is
shutdown by an unforeseen accident such as power interruption,
turn on the power again as soon as possible. The rebuild is
automatically restarted.
The interval from the removal of the defected HDD to the
installation of a substitute HDD should be 90 sec or longer.
If the hot-swap rebuild does not operate, perform the manual
rebuild.
The following hard disk drive cannot be specified as a hot spare
disk.
– Hard disk drive with partitions
– Hard disk drive used for another array
Prepare another new hard disk drive or a formatted hard disk drive.