Release 6.0
213
User Guide
Chapter 7 Initializing a Disk Array (SAS)
Perform the following steps to select the setting type:
1. Select the setting type for initialization.
The sections below explain how to make normal setting.
2. Confirm whether
Normal Setting
is selected, and then click
Next
.
Parameter
Description
Normal Setting
Settings are performed step by step. Select this option in general.
Quick Setting
A RAID6/60 pool, hot spares, and logical disks are automatically bound
at once by using all the unused physical disks. All the logical disks
become available to all application servers.
This setting is available to a configuration that satisfies all the following
conditions:
7 or more unused physical disks of the same type, same capacity, and
same rotating speed
Windows, Linux, VMware, or Hyper-V host
To perform quick setting, see
NEC Storage Software Configuration Setting Tool User's
Manual (GUI) for the M Series
.
Quick Setting cannot be used for the disk arrays of the M300 series or
later.
Quick Setting cannot be used when Access Control is enabled.
Quick Setting cannot be used if unused physical disk are different in
type, capacity or rotation speed.
Содержание M100
Страница 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Страница 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Страница 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Страница 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Страница 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Страница 75: ...Release 6 0 75 User Guide Chapter 3 Installing the Disk Array System Figure 3 10 Securing Unit 2 ...
Страница 88: ...Release 6 0 88 User Guide Chapter 4 NEC Storage Manager Figure 4 1 Example of Recommended Configuration ...
Страница 125: ...Release 6 0 125 User Guide Chapter 4 NEC Storage Manager d Click Login to open the main screen Figure 4 26 Main Screen ...
Страница 194: ...Release 6 0 194 User Guide Chapter 6 Initializing a Disk Array iSCSI Figure 6 16 Hot Spare Bind View Display ...
Страница 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Страница 388: ...Release 6 0 388 User Guide Appendix F How to Set Check Application Server Linux iSCSI Figure F 3 Configuration Example ...
Страница 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...