Release 6.0
274
User Guide
Chapter 10 Troubleshooting
LNK/ACT LED (green)
of the management port
is out, or blinks
When connecting a cable to the management port, LNK/ACT LED
(green) may not turn on because of the following causes.
The power of the HUB, switch, or server to connect to has not been
turned on.
The power supply of the HUB, switch, or server to connect to is at
fault.
The cable type is wrong.
A cross cable and straight cable are not recognized automatically. Use
a cable following the predetermined connection method.
The Speed and Duplex settings do not match.
Auto Detect is set as default. Since connecting to a device in Full
Duplex mode could cause abnormal operation, set Auto Detect or Half
Duplex to the device to connect.
(To set Full Duplex, ask your sales or maintenance service agent.)
Depending on the type of hub, it may remain off or it may blink.
SPEED LED
(Green/Orange) of the
management port is on
or blinks
This is not a fault.
SPEED LED (Green/Orange) is on when connection is established
through the disk array unit monitoring protocol with a cable connected to
the management port. If the cable is removed from the unit, SPEED LED
briefly remains on.
Table 10-2: Trouble in Disk Array Unit (Rear Panel Controller LED Status) (Contd.)
Condition
Cause and Action
Table 10-3: Trouble in Disk Array Unit or Disk Enclosure (Rear Panel Power LED Status)
Condition
Cause and Action
INPUT GOOD LED
(green) is on, FAULT
LED (orange) is off, and
DC GOOD LED (green)
is on
This is not a fault.
This indicates that AC input is being supplied to the unit and DC output is
in normal operation.
INPUT GOOD LED
(green) is off.
AC input is not being supplied.
Check whether the power supply cable is correctly connected. If the
cable is correctly connected, replace the power supply.
INPUT GOOD LED
(green), FAULT LED
(orange), and DC
GOOD LED (green) are
on
This indicates that the power fan error was detected or the temperature
within the power supply reached the warning value (the detected
temperature was more than 55 degrees Celsius (131°F)).
The unit has dual power supply configuration.
Therefore, SERVICE LED turns on when FAULT
LEDs of both PS0 and PS1 are on.
Содержание M100
Страница 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Страница 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Страница 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Страница 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Страница 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Страница 75: ...Release 6 0 75 User Guide Chapter 3 Installing the Disk Array System Figure 3 10 Securing Unit 2 ...
Страница 88: ...Release 6 0 88 User Guide Chapter 4 NEC Storage Manager Figure 4 1 Example of Recommended Configuration ...
Страница 125: ...Release 6 0 125 User Guide Chapter 4 NEC Storage Manager d Click Login to open the main screen Figure 4 26 Main Screen ...
Страница 194: ...Release 6 0 194 User Guide Chapter 6 Initializing a Disk Array iSCSI Figure 6 16 Hot Spare Bind View Display ...
Страница 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Страница 388: ...Release 6 0 388 User Guide Appendix F How to Set Check Application Server Linux iSCSI Figure F 3 Configuration Example ...
Страница 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...