Chapter 10 Troubleshooting
10.4.2 iSCSI Setup Tool (Linux) Errors
Problem
Cause and Solution
The message, "File not found." is
displayed.
A file that is specified as a parameter file does not exist.
Specify the file name correctly.
The message, "iSCSI Initiator is not
installed." is displayed.
iSCSI Initiator is not installed.
Install iSCSI Initiator, start the service, and then re-start
iSCSI Setup Tool.
The message, "The parameter is
invalid." is displayed.
The format of IP addresses of host connection ports
specified in the parameter file is invalid.
Modify the parameter file and re-start the iSCSI Setup Tool.
The message, "No parameter is set."
is displayed.
Valid parameters are not entered in the parameter file.
Modify the parameter file and re-start iSCSI Setup Tool.
The message, "Please enter serial
number." is displayed.
A serial number is not entered in the parameter file.
Modify the parameter file and re-start iSCSI Setup Tool.
The message, "Please enter target IP
address." is displayed.
The IP addresses of host connection ports are not specified
in the parameter file.
Modify the parameter file and re-start iSCSI Setup Tool.
The message, "Please enter the
target CHAP secret." is displayed.
The target CHAP secret is specified but no CHAP initiator
secret is specified in the parameter file.
Modify the parameter file and re-start iSCSI Setup Tool.
The message, "The tool has already
been started." is displayed.
The iSCSI Setup Tool is already is up and running.
Terminate the running iSCSI Setup Tool, and then restart it.
The message, "Invalid host name." is
displayed.
A character other than alphanumeric characters or hyphen
(-) is used for a server host name.
Change the host name using only alphanumeric characters
or hyphen (-) based on the restrictions of creating target.
After changing the host name, restart the iSCSI Setup Tool.
The message, "Failed to collect the
serial numbers. Error code:xxxx" is
displayed.
An error occurred in retrieving the serial number.
For details, see
Section 10.4.3: “iSCSI Setup Tool Error
The message, "No management port
of the disk array is not set." is
displayed.
The management port settings are not configured to the
disk array.
Set the management port and start the iSCSI Setup Tool
again.
The message, "Host connection ports
of the disk array are not set." is
displayed.
The host post connection settings are not configured.
See
Section 6.2.1: “Initialization Wizard”
to perform the
initialization to configure the host connection port settings.
Then, run the iSCSI Setup Tool again.
Содержание M100
Страница 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Страница 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Страница 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Страница 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Страница 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Страница 75: ...Release 6 0 75 User Guide Chapter 3 Installing the Disk Array System Figure 3 10 Securing Unit 2 ...
Страница 88: ...Release 6 0 88 User Guide Chapter 4 NEC Storage Manager Figure 4 1 Example of Recommended Configuration ...
Страница 125: ...Release 6 0 125 User Guide Chapter 4 NEC Storage Manager d Click Login to open the main screen Figure 4 26 Main Screen ...
Страница 194: ...Release 6 0 194 User Guide Chapter 6 Initializing a Disk Array iSCSI Figure 6 16 Hot Spare Bind View Display ...
Страница 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Страница 388: ...Release 6 0 388 User Guide Appendix F How to Set Check Application Server Linux iSCSI Figure F 3 Configuration Example ...
Страница 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...