Release 6.0
396
User Guide
Appendix F How to Set/Check Application Server (Linux) (iSCSI)
e. Execute the following commands.
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /1/> --op update -n
node.session.auth.authmethod -v CHAP
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /1/> --op update -n
node.session.auth.username -v <initiator name>
iscsiadm -m node --targetname <target name
specified in step /a/> -p <target IP addresss
succeeded to log on in step /a/> --op update -n
node.session.auth.password -v <CHAP password for
the initiator>
f. If you use mutual CHAP authentication, execute the following
commands.
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in step 1.> --op update -n
node.session.auth.username_in -v <target name
specified in step a.>
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in step a.> --op update -n
node.session.auth.password_in -v <CHAP password for
the target>
g. Execute the following command.
(If there are two or more IP addresses succeeded to log on, repeat
the steps e-g)
iscsiadm -m node --targetname <target name
specified in step a.> -p <target IP address
succeeded to log on in the step a.> -l
* If you use three or more disk arrays, repeat the procedures in steps
a-b repeatedly, and then perform the procedure in step c for the last
disk array unit. And then perform the procedure the steps d–g
repeatedly for each disk arrays you have done the procedures in step
a-b.)
Содержание M100
Страница 25: ...Release 6 0 25 User Guide About Warning Labels Power Supply AC Power Supply ...
Страница 27: ...Release 6 0 27 User Guide About Warning Labels Battery ...
Страница 29: ...Release 6 0 29 User Guide About Warning Labels Power Cable AC Power Supply ...
Страница 40: ...Release 6 0 40 User Guide Chapter 1 Overview 1 2 1 4 Controller CONT ...
Страница 48: ...Release 6 0 48 User Guide Chapter 1 Overview 1 2 3 3 Controller CONT ...
Страница 75: ...Release 6 0 75 User Guide Chapter 3 Installing the Disk Array System Figure 3 10 Securing Unit 2 ...
Страница 88: ...Release 6 0 88 User Guide Chapter 4 NEC Storage Manager Figure 4 1 Example of Recommended Configuration ...
Страница 125: ...Release 6 0 125 User Guide Chapter 4 NEC Storage Manager d Click Login to open the main screen Figure 4 26 Main Screen ...
Страница 194: ...Release 6 0 194 User Guide Chapter 6 Initializing a Disk Array iSCSI Figure 6 16 Hot Spare Bind View Display ...
Страница 260: ...Release 6 0 260 User Guide Chapter 8 Installing Optional Parts Figure 8 12 Removing the DIMMs ...
Страница 388: ...Release 6 0 388 User Guide Appendix F How to Set Check Application Server Linux iSCSI Figure F 3 Configuration Example ...
Страница 459: ...NEC Corporation 7 1 Shiba 5 chome Minato ku Tokyo 108 8001 Japan URL http www necstorage com ...