7-4 Troubleshooting
POST Error Messages
Powering on the server automatically starts the self-diagnostic program, POST (Power On
Self-Test). When POST detects any error, it displays an error message and its measure on the
display unit. Follow the table below to troubleshoot such errors.
Phoenix BIOS 4.0 Release 6.0.XXXX
:
CPU=Pentium III XXX MHz
0640K System RAM Passed
0127M Extended RAM Passed
WARNING:
02B0: Diskette drive A error.
:
press <F1> to resume, <F2> to SETUP
Message indicating a floppy disk drive error
TIPS:
For error messages on optional PCI boards, refer to the manual provided with those options.
On-screen error message
Cause
Action
0200 Failure Fixed Disk
•
HDD is faulty
•
CPU/IO module is faulty.
•
Replace the HDD.
•
Replace the CPU/IO module.
0210 Stuck Key
Keyboard connection error
•
Disconnect the keyboard and
connect it back again.
•
Replace the keyboard.
0211 Keyboard error
Keyboard is faulty.
•
Disconnect the keyboard and
connect it back again.
•
Replace the keyboard.
•
If restarting does not help,
replace the CPU/IO module.
0212 Keyboard Controller
Failed
Keyboard controller is faulty.
If restarting the server does not
help, replace the CPU/IO module.
0213 Keyboard locked -
Unlock key switch
Keyboard is locked.
Unlock the key switch.
0230 System RAM Failed at
offset
DIMM is faulty.
•
Replace DIMM.
•
Replace the CPU/IO module.
0231 Shadow RAM Failed at
offset
Shadow RAM is faulty.
•
Replace DIMM.
•
Replace the CPU/IO module.
0232 Extended RAM Failed at
address line
Extended RAM is faulty.
•
Replace DIMM.
•
Replace CPU/IO module.
0233 Memory type mixing
detected
Memory of the different types
is installed.
Memory of the different types is
installed. Replace DIMM with
appropriate one.
0250 System battery is dead
-Replace and run
SETUP
System battery is dead.
•
Replace system battery.
•
Replace CPU/IO module.
Содержание Express5800/320Fd-MR
Страница 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Страница 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 43: ...2 10 General Description Rear View...
Страница 47: ...2 14 General Description CPU IO Module CPU IO module...
Страница 67: ...2 34 General Description This page is intentionally left blank...
Страница 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Страница 80: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner...
Страница 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Страница 198: ...4 92 System Configuration This page is intentionally left blank...
Страница 233: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 370: ......
Страница 371: ...This page is intentionally left blank...
Страница 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Страница 391: ...6 20 Maintenance This page is intentionally left blank...
Страница 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Страница 480: ......
Страница 483: ......