5-154 Installing and Using Utilities
Committing the Upgrade
When you are finished testing your applications on the merged system, and you are satisfied that
everything is working correctly, you can commit the upgrade to make it permanent.
Committing the upgrade
•
Rebuild the mirror of any internal RDR system disk by overwrititing the original partner disk
with its newer, upgraded partner disk.
•
Rebuild the mirror of any internal RDR data disk by overwriting the stale partner disk with its
newer, activated disk. The stale disk refer to the one that your applications have been writing
data throughout the upgrade process.
•
Does not restart your applications, as they are already running on the upgraded system. There
is no additional downtime.
CAUTION:
You cannot abort the upgrade process after you commit an upgrade
because the original
state of the system is lost (overwritten) as a result of completing the upgrade process. Ensure
that your system is working as expected before clicking
Commit
.
How to commit the upgrade
1.
Close all non-essential applications.
2.
Verify that the upgrade state, as reported in the status bar, is
Fault Tolerant\Merge\Ready
.
3.
Click
Commit
.
IMPORTANT:
Your screen might flicker and you might briefly lose control of your keyboard and mouse as
the system commits the upgrade.
The commit process should take only a few minutes. After it completes, the upgrade state is
Fault
Tolerant\Commit\Ready
. You can click
Finish
to clean up ft series resources, as described in
“Finishing the Upgrade” on page 5-157.
If the commit process fails the first time, you can click
Retry
to try again. If the problem persists,
see “Troubleshooting” for information about resolving the problem.
Содержание Express5800/320Fd-MR
Страница 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Страница 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 43: ...2 10 General Description Rear View...
Страница 47: ...2 14 General Description CPU IO Module CPU IO module...
Страница 67: ...2 34 General Description This page is intentionally left blank...
Страница 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Страница 80: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner...
Страница 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Страница 198: ...4 92 System Configuration This page is intentionally left blank...
Страница 233: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 370: ......
Страница 371: ...This page is intentionally left blank...
Страница 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Страница 391: ...6 20 Maintenance This page is intentionally left blank...
Страница 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Страница 480: ......
Страница 483: ......