System Configuration 4-21
The table below lists how selections for “AC LINK” determine the power status of the server when
the power supply to the server restarts.
Parameter
State before powered off
Stay Off
Last State
Power On
In
service
Off On On
Out of service (DC power: Off)
Off
Off
On
Forced
shutdown
*
Off Off On
* Pressing the POWER switch for over four seconds shuts down the power to the server.
System Management
Select “System Management” on the Server menu and press
Enter
to display the following screen.
〈Example〉
See the table below for setup options on the screen.
Option Parameter
Description
BIOS Version
Displays the BIOS version.
Board Part Number
Displays the board information.
Board Serial Number
Displays the board information.
System Part Number
Displays the system information.
System Serial Number
Displays the system information.
Chassis Part Number
Displays the chassis information.
Main Advanced Security
Server
Boot Exit
ftServer Setup
F1 Help ↑↓ Select Item -/+ Change Values F9 Setup Defaults
Esc Exit ←→ Select Menu Enter Select Sub Menu F10 Save and Exit
System Management
Item Specific Help
All items on this menu
cannot be modified in
user mode. If any
items require changes,
please consult your
system Supervisor.
BIOS Version: 2.1:44
Board Part #: 243-632791
Board Serial #: 113108030768
System Part #: N8800-103
System Serial #: 9072543618
Chassis Part #: 243-535509
Chassis Serial #: 01
BMC Device ID: 26
BMC Device Rev: 01
BMC Firmware Rev: 0E.25
SDR Rev: SDR Version 00.10
PIA Rev: 01.10
ASIC Rev: 2023
SMM Rev: 00.25
Содержание Express5800/320Fd-MR
Страница 13: ...v Appendix B I O Port Addresses This appendix lists factory assigned I O port addresses...
Страница 19: ...xi THIS PAGE IS INTENTIONALLY LEFT BLANK...
Страница 43: ...2 10 General Description Rear View...
Страница 47: ...2 14 General Description CPU IO Module CPU IO module...
Страница 67: ...2 34 General Description This page is intentionally left blank...
Страница 79: ...3 12 Windows Setup and Operation 3 Confirm that RDR of the disk is cancelled...
Страница 80: ...Windows Setup and Operation 3 13 4 Cancel the disk of the corresponding slot in the same manner...
Страница 106: ...Windows Setup and Operation 3 39 This page is intentionally left blank...
Страница 198: ...4 92 System Configuration This page is intentionally left blank...
Страница 233: ...Installing and Using Utilities 5 35 DIMM Allows the information of DIMM on the CPU modules to be viewed...
Страница 370: ......
Страница 371: ...This page is intentionally left blank...
Страница 389: ...6 18 Maintenance 3 Stop of PCI module 1 4 Start of PCI module 1...
Страница 391: ...6 20 Maintenance This page is intentionally left blank...
Страница 465: ...System Upgrade 8 31 board must not be mixed with N8804 005 or N8803 035...
Страница 480: ......
Страница 483: ......